Skip to content

Water Scale Dissolving

“Eco-Friendly Excellence: Revolutionizing Industrial Cleaning with Biodegradable Solutions”

Chemical Cleaning Services

What is Rydlyme Descaler?

RYDLYME is the trade name of our scientifically formulated descaler. RYDLYME is specifically designed to dissolve the toughest water scale, struvite/vivianite, lime, calcium and rust deposits from virtually any equipment which utilizes water.
This powerful, yet totally safe, liquid descaler is non-toxic, non- injurious, non-flammable, non-hazardous, non-corrosive and BIODEGRADABLE; so RYDLYME will not harm your personnel, equipment or our environment!

Why Choose Rydlyme Descaler?

Efficiency: It dissolves approximately 1kg of scale per 4 litres!
Non-Hazardous: It does not fall under designated classes of hazardous waste!
Biodegradable: It has a biochemical oxygen demand of 16 mg/l and can be disposed of through normal plant sewers!
Safety: It can be held in the open hand without injury!
Economical: An investment in RYDLYME can multiply your efficiency!
Approved: Worksafe, USDA, FDA, Kosher, U.S. Navy, Australian Navy, and many others!

SONY DSC

Heat Exchanger Descaler

Descaling heat exchangers is crucial for maintaining their efficiency and performance. Over time, scale deposits like calcium carbonate, rust, and other minerals can build up on the heat transfer surfaces, reducing efficiency and increasing energy consumption.

Simply circulate by RYDLYME Biodegradable Descaler through the heat exchanger tubes removing  mineral and scale build up in a safe and timely manner.

Descaling Process

  1. Isolation: Shut down the heat exchanger and isolate it from the system.
  2. Preparation: Drain the heat exchanger and flush it to remove any loose debris.
  3. Application: Use a descaling solution (e.g., RYDLYME, ScaleBreak) to dissolve scale deposits.
  4. Circulation: Circulate the descaling solution through the heat exchanger for the recommended time.
  5. Rinsing: Thoroughly rinse the heat exchanger to remove any residual descaler and contaminants.
  6. Recommissioning: Refill the heat exchanger with water and restart the system.

Boiler Tube Descaler

Boiler tube cleaning is made easy with RYDLYME Biodegradable Descaler due to the chemical’s unique attributes. As RYDLYME is circulated throughout the boiler system, the descaler will remove mineral deposits and clean boiler tubes of scale that dramatically increases your fuel consumption.

Descaling Process

  1. Isolation: Shut down the boiler and isolate it from the system.
  2. Preparation: Drain the boiler and flush it to remove any loose debris.
  3. Application: Use a descaling solution (e.g., RYDLYME, ScaleBreak) to dissolve scale deposits2.
  4. Circulation: Circulate the descaling solution through the boiler tubes for the recommended time.
  5. Rinsing: Thoroughly rinse the boiler to remove any residual descaler and contaminants.
  6. Recommissioning: Refill the boiler with water and restart the system.

Pipeline Descaler

Pipeline descaling is the process of removing scale deposits, such as calcium carbonate, rust, and other contaminants, from the interior surfaces of pipelines. This is crucial for maintaining flow efficiency and preventing blockages.

Descaling Process

  1. Isolation: Bypass the pipeline from operation and remove existing water.
  2. Preparation: Disconnect the pipeline connections and attach hoses to a circulation pump and tank.
  3. Application: Use a descaling solution (e.g., Dynamic Descaler, Alpha Descaler, ScaleBreak) to dissolve scale deposits.
  4. Circulation: Circulate the descaling solution through the pipeline for the recommended time.
  5. Rinsing: Thoroughly rinse the pipeline to remove any residual descaler and contaminants.
  6. Recommissioning: Reconnect the pipeline connections and refill the system with water.

Chillers & Condensers Descaler

Descaling chillers and condensers is essential for maintaining their efficiency and performance. Over time, minerals like calcium carbonate, rust, and other contaminants can build up on the heat transfer surfaces, reducing efficiency and increasing energy consumption

Descaling Process

  1. Isolation: Bypass the chiller or condenser from operation and remove existing water.
  2. Preparation: Disconnect the water in/out connections and attach hoses to a circulation pump and tank.
  3. Application: Use a descaling solution (e.g., Dynamic Descaler, Alpha Descaler, ScaleBreak) to dissolve scale deposits3.
  4. Circulation: Circulate the descaling solution through the system for the recommended time.
  5. Rinsing: Thoroughly rinse the system to remove any residual descaler and contaminants.
  6. Recommissioning: Reconnect the water in/out connections and refill the system with water.
Rydlym

Biodegradable chemical

A safe to use and eco-friendly alternative to some of the more hazardous and highly flammable solvent degreasers currently on the market!

“Cleaner Solutions, Greener Future: Biodegradable Chemical Cleaning for Industrial Excellence”